단일 카메라 마커리스 3D 동작분석의 어깨 관절가동범위 측정 신뢰도·타당도 검증

원제: Reliability and Validity of the Single-Camera Markerless Motion Capture System for Measuring Shoulder Range of Motion in Healthy Individuals and Patients with Adhesive Capsulitis: A Single-Center Study

Lee S, Lee U, Kim Y, Noh S, Lee H, Lee S

대표 논문교신저자인용 1회

관련 연구 분야:근골격계 통증 질환3D 동작분석 기술

요약

연구 질문
카메라 한 대로 작동하는 마커리스 동작분석 시스템(iBalance)이 어깨 관절가동범위를 믿을 만하게 측정하는지 확인하고자 했습니다.
연구 방법
건강인 30명과 유착성 관절낭염 환자 10명, 어깨 동작 7가지를 평가자 2명이 iBalance와 각도계로 3회씩 측정하고 1주 후 반복 (단일기관 예비연구).
주요 결과와 한계
굴곡·외전·수동 외전에서 평가자 간·내 신뢰도가 우수했고(ICC 0.91–0.98) 각도계와의 타당도도 높았습니다(ICC 0.85–0.97). 환자군은 변동이 더 컸고 이상반응은 없었습니다. 나머지 동작의 성능은 추가 개선이 필요합니다.

초록에 근거해 정리한 요약입니다. 원문을 함께 확인해 주세요.

초록

Assessing shoulder joint range of motion (ROM) is essential for diagnosing musculoskeletal disorders and optimizing treatments. This single-center pilot study evaluated the reliability and validity of iBalance, a single-camera markerless motion capture system, for measuring shoulder ROM. Forty participants (30 healthy individuals and 10 patients with adhesive capsulitis) underwent measurements of seven shoulder joint movements. Each movement was assessed three times by two raters using both iBalance and a goniometer, with measurements repeated after 1 week. The iBalance demonstrated excellent inter- and intra-rater reliability for flexion (ICC = 0.93 [0.91-0.95], 0.91 [0.88-0.94]), abduction (ICC = 0.97 [0.95-0.98], 0.93 [0.91-0.95]), and passive abduction (ICC = 0.97 [0.96-0.98], 0.98 [0.97-0.98]). The system also showed strong validity compared to the goniometer for flexion (ICC = 0.85 [0.68-0.92]), abduction (ICC = 0.95 [0.94-0.96]), and passive abduction (ICC = 0.97 [0.96-0.98]). Bland-Altman plots showed high consistency between the two devices for flexion, abduction, and passive abduction, with most data points falling within the limits of agreement. Patients with adhesive capsulitis exhibited greater variability than healthy individuals. No adverse events were reported, supporting the safety of the system. This study highlights the potential of a single-camera markerless motion capture system for diagnosing and treating shoulder joint disorders. The iBalance showed clinical applicability for measuring flexion, abduction, and passive abduction. Future enhancements to the algorithm and the incorporation of advanced metrics could improve its performance, facilitating broader clinical applications for diagnosing complex shoulder conditions.

출처: PubMed. 원문을 그대로 인용했습니다.